G8 Controller Specifications
Station Assignments
- G8 Stations capacity: 4 standard, expandable to 8 zones.
- Pair of Soil Probes: one per watering zone. Minimum 1, maximum 4 per controller.
- Zone 1: must be driven by soil probes.
- Zone 2: driven by soil probes or set to track zone 1 watering schedule.
- Zone 3 and 4: track zone 1 watering schedule.
- Zone 5: driven by soil probes or track zone 1.
- Zone 6: driven by soil probes or set to track zone 5 watering schedule.
- Zone 7 and 8: track zone 5 watering schedule.
- Each zone POWER indicator: Green LED, lit during watering.
- Soil wire pair OPEN indicator: Red LED.
- Soil wire pair SHORTENED: Red LED.
- Manual operation: Green LED.
- G8 is powered by 24VAC solenoid drive from a zone activated by a Sprinkler Timer.
- Power consumption: 24VAC @ 90mA.
- G8 automatically overrides Timer settings to provide needed run-times and frequency of watering.
- The pair of soil probes: 2" L x 0.75" W, non corrosive sheet metal.
- Soil probes wires: #16 or better, direct bury, maximum length 800 feet.
- Each zone may be individually bypassed and reverted to a manual control.
Indicators
Electrical